Registration Dossier

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP-like

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Relative self-ignition temperature (solids)
Remarks on result:
other: The test item doesn't reaeh 400 oc by self heating

Applicant's summary and conclusion

Conclusions:
The test item C-SAT 120007 doesn't reach 400°C by self heating. Therefore the test item has no Relative Self-lgnition Temperature according to the definition in the Council Regulation (EC) No 440/2008, method A. 16.