Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Cross-reference
Reason / purpose for cross-reference:
reference to other study
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 SEP 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
not specified
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
162.2 °C
Atm. press.:
102.4 kPa
Remarks on result:
other: Only one measurement is made, because the material tends to polymerise at these temperatures, what results in excessive cleaning effort.
Flash point:
161.9 °C
Atm. press.:
101.325 kPa
Remarks on result:
other: Result corrected to 101.325 kPa.
Interpretation of results:
other: EU GHS criteria not met
Conclusions:
Flash point = 162.2 °C at 102.4 kPa
Flash point = 161.9 °C at 101.325 kPa
Executive summary:

The flash point of the test substance has been determined to be 162.2 °C at 102.4 kPa (EN ISO 2719, no GLP, 2012). After correction of the pressure to 101.325 kPa, this results in a flas point of 161.9 °C.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion