Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Currently viewing:

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
(Q)SAR
Adequacy of study:
key study
Study period:
2019
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE
EpiSuite BIOWIN v.4.10

2. MODEL (incl. version number)
BIOWIN v.4.10

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
CAS-Number: 502-49-8
Smiles: O=C(CCCCCC1)C1
Name: Cyclooctanone

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
The program BIOWIN estimates the probality of biodegradation of organic compunds and consists of seven models. The model is well accepted for prediction of biodegradation. Further description see Boethling et al. 2003. For interpretation of the models see also ECHA guidance document chapter R.7b.

5. APPLICABILITY DOMAIN
A precise definition of the applicability domain is not available, however the molecular weight range of the training set (MW range of 30 to 959) and the precence and number of functional groups should be considered.

6. ADEQUACY OF THE RESULT
The test substance is considered to be inside the applicability domain of the EpiSuite BIOWIN model since the following criteria are fulfilled (as described in the model's manual):
- the molecular weight is within the molecular weight range of the training set
- The test substance has a limited number of functional groups
- all functional groups present in the test substance are represented in the training set and have a fragment coefficient available.
Therefore, the prediction is considered to be valid and reliable.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report date:
2019

Materials and methods

Test guideline
Guideline:
other: ECHA guidance on QSAR, Chapter R.6
Deviations:
no
Principles of method if other than guideline:
To estimate the biodegradability of the test substance, the validated QSAR model BIOWIN v.4.10 (US EPA) has been used.
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Cyclooctanone
EC Number:
207-940-2
EC Name:
Cyclooctanone
Cas Number:
502-49-8
Molecular formula:
C8H14O
IUPAC Name:
cyclooctanone
Specific details on test material used for the study:
Smiles: O=C(CCCCCC1)C1

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
activated sludge (adaptation not specified)

Results and discussion

% Degradation
Remarks on result:
readily biodegradable based on QSAR/QSPR prediction
Remarks:
The percentage of degradation has not been calculated.
Details on results:
The percentage of degradation has not been calculated. The calculation was for predicting whether the substance is ready biodegradable or not.
The overall prediction of the model is: Ready biodegradability: yes. The test substance is predicted to be readily biodegradable.

Any other information on results incl. tables

Probability of Rapid Biodegradation (BIOWIN v4.10): 

Model #

Outcome

Interpretation of the model

    Biowin1 (Linear Model)

  0.6943

 biodegrades fast

 Biowin2 (Non-Linear Model)

 0.6821

 biodegrades fast

 Biowin3 (Ultimate Survey Model):

2.8978 (weeks )

 Biodegradation fast (weeks)

 Biowin4 (Primary Survey Model) :

 3.6434 (days-weeks )

 Biodegradation fast (days-weeks)

 Biowin5 (MITI Linear Model)

 0.5925

 biodegrades fast

 Biowin6 (MITI Non-Linear Model)

 0.7976

 biodegrades fast

 Biowin7 (Anaerobic Linear Model)

 -0.3959

 Does not biodegrade fast

 Ready Biodegradability Prediction:

YES

Applicant's summary and conclusion

Validity criteria fulfilled:
not applicable
Interpretation of results:
readily biodegradable
Conclusions:
The test substance is estimated to be readily biodegradable by using the method BIOWIN v.4.10.