Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-04-11
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
ASTM D 7094-04 Pensky Martens closed cup
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
172 °C
Atm. press.:
101.3 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point: 445 K (172 ºC)
Executive summary:

Flash point: 445 K (172 ºC)

Description of key information

Flash point: 445 K (172 ºC)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
172 °C

Additional information