Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
migrated information: read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
2867-59-6
Cas Number:
2867-59-6
IUPAC Name:
2867-59-6
Details on test material:
- Name of test material (as cited in study report): 3-Amino-1-butanol
- Analytical purity: pure 100 %
- Impurities (identity and concentrations): 0 %
- Isomers composition: racemate mixture
- Lot/batch No.: VS1164/YA1256 Fr.13-27

Results and discussion

Flash point
Flash point:
92 °C
Atm. press.:
1 013.25 hPa

Applicant's summary and conclusion