Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report Date:
2006

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
51 °C
Vapour pressure:
0.018 Pa
Remarks on result:
other: First vapour pressure
Temp.:
44 °C
Vapour pressure:
0.012 Pa
Remarks on result:
other: Second vapour pressure
Temp.:
25 °C
Vapour pressure:
0.004 Pa
Remarks on result:
other: Estimated vapour pressure

Applicant's summary and conclusion