Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
substances / mixtures which in contact with water emit flammable gases
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 29, 2013 - November 7, 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was performed in accordance with the UN-MTC Section 33 (Test N.5) and EC.A.12 guideline and complied with the principles of GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
other: UN ST/SG/AC.10/11/Rev.5: Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, Part III, Section 33 (33.4.1.4) “Test N.5: Test method for substances which in contact with water emit flammable gases” (2009)
Deviations:
no
Qualifier:
according to
Guideline:
EU Method A.12 (Flammability (Contact with Water))
Version / remarks:
(2008)
Deviations:
no
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): KF-1622
- Description: Clear colourless liquid
- Storage condition of test material: In refrigerator (2-8°C) in the dark
- Expiration date of the lot/batch: May 17, 2014

Results and discussion

Any other information on results incl. tables

No evolution of a gas and/or spontaneous ignition of the test substance in contact with water was observed in Test 1, Test 2, Test 3 and Test 4.

Applicant's summary and conclusion

Interpretation of results:
other: ‘not highly flammable’ in contact with water
Conclusions:
The substance was determined to be ‘not highly flammable’ in contact with water in a GLP-compliant study performed in accordance with UN-MTC Section 33 (Test N.5) and EC.A.12.