Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Principles of method if other than guideline:
The purpose of the study is the determination of the flash point by rapid equilibrium closed cup method according to ISO 3679
GLP compliance:
not specified
Type of method:
equilibrium method closed cup
Flash point apparatus:
other: Normlab Flash Point – NPV 310 Model

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Type:
Constituent
Type:
Constituent
Type:
impurity
Type:
impurity
Type:
impurity
Test material form:
liquid

Results and discussion

Flash point
Flash point:
199 °C
Atm. press.:
1 007.8 hPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point was measured to be 199 degrees C in a closed cup apparatus.
Executive summary:

The flash point was measured to be 199 degrees C in a closed cup apparatus.