Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
3 (not reliable)
Rationale for reliability incl. deficiencies:
other: The result was obtained from a number of publically available sources which have been subject to peer-review and in which the original data sources are traceable. A great deal of variability was seen for this endpoint.

Data source

Referenceopen allclose all

Reference Type:
other: Database
Title:
3-Chloropropane-1,2-diol
Year:
2000
Bibliographic source:
IUCLID dataset, ESIS, European Chemical Bureau
Reference Type:
other: Database
Title:
3-Chloro-1,2-propanediol
Bibliographic source:
IFA Gesitis Substance database
Reference Type:
publication
Title:
Unnamed
Year:
2006
Reference Type:
other company data
Title:
Unnamed

Materials and methods

GLP compliance:
not specified

Test material

Constituent 1
Reference substance name:
3-chloropropane-1,2-diol
EC Number:
202-492-4
EC Name:
3-chloropropane-1,2-diol
Cas Number:
96-24-2
IUPAC Name:
3-chloropropane-1,2-diol
Constituent 2
Reference substance name:
3-Chloro-1,2-propanediol
IUPAC Name:
3-Chloro-1,2-propanediol

Results and discussion

Vapour pressureopen allclose all
Temp.:
25 °C
Vapour pressure:
0.022 hPa
Remarks on result:
other: ESIS result
Temp.:
20 °C
Vapour pressure:
0.01 mBar
Remarks on result:
other: IFA Gestis result
Temp.:
115 °C
Vapour pressure:
13 mBar
Remarks on result:
other: EPA result
Temp.:
20 °C
Vapour pressure:
71 hPa
Remarks on result:
other: Solvay SDS result

Applicant's summary and conclusion

Conclusions:
The vapour pressure data is quite variable but for the purposes of this dossier the value shall be 71hPa at room temperature.