Registration Dossier

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes (incl. certificate)
Type of method:
oscillating densitimeter

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name of test material (as cited in study report): "Diethylentriamine R" (Reaction products of 2-aminoethanol with ammonia)
Batch-No.: AM385290H0
Analytical purity: The test item is a complex mixture of a large number of individual components. Main components are 2-(2-aminoethylamino)ethanol (10-80 % (w/w)) and N-N’-bis(2-aminoethyl)ethane-1,2-diamine (5-50 % (w/w))

Results and discussion

Density
Type:
relative density
Density:
1.032
Temp.:
20 °C

Any other information on results incl. tables

  1st
determination
2nd
determination
density of the test item [g/cm3] 1.0316 1.0316

relative density D(20/4)
(densitytdensity of water at 4°C)

1.0316 1.0136

mean

1.0316
Measuring temperature = 20 °C
The estimated accuracy is +/-0.0001 g/cm3

Applicant's summary and conclusion