Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
> 300 °C
Atm. press.:
1 013 hPa

Description of key information

Flash point: > 300 °C (ASTM 93B)

Key value for chemical safety assessment

Additional information

The flash point of the substance Glycerides, C16-18 and C18-unsatd. mono- and di-, citrates (CAS 91052-16-3) was determined by Pensky Martens closed cup tester according to ASTM D 93B.