Registration Dossier

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
density, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: ASTM D-4052
Principles of method if other than guideline:
This test method covers the laboratory determination using a glass hydrometer of the density of petroleum products normally handled as liquids and having a Reid vapour pressure od 101.325 kPa or less. Values are measured at the reference temperature.
GLP compliance:
not specified
Type of method:
other: ASTM D 1298
Type:
density
Density:
0.871 g/L
Temp.:
15 °C
Remarks on result:
other: The specification for the density at 15°C is 0.868 - 0.876 g/l
Conclusions:
The sustance has a density ranging from 0.868 to 0.876 at 15°C
Endpoint:
density, other
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Principles of method if other than guideline:
This test method covers the laboratory determination using a glass hydrometer of the density of petroleum products normally handled as liquids and having a Reid vapour pressure od 101.325 kPa or less. Values are measured at the reference temperature.
GLP compliance:
not specified
Type of method:
other: ASTM D 1298
Type:
density
Density:
0.87 g/L
Temp.:
15 °C
Remarks on result:
other: The specification for the density at 15°C is 0.868 to 0.876 g/l
Conclusions:
The dentity of the substance is ranging from 0.868 to 0.876 mg/L at 15°C

Description of key information

There are two measurements available done according ASTM D-4052, with identical results.

One measurement was done by an external certified testing laboratory and the other was done in-company.

Key value for chemical safety assessment

Relative density at 20C:
0.871

Additional information