First-aid measures

Description of first aid measures
Pay attention to self-protection.
Remove victims from hazardous area. Immediately remove soiled or soaked clothing and remove it to a safe distance. Keep victim warm, in a stabilized position and covered.
Do not leave victims unattended.
If the casualty is unconscious: Place the victim in the recovery position.

Inhalation:
Potential for exposure by inhalation if aerosols or mists are generated.
After inhalation move subject to fresh air.
With labored breathing: Provide with oxygen. Consult a doctor.
If the casualty is not breathing: Perform mouth-to-mouth resuscitation, notify emergency physician immediately.

Skin contact:
Wash off affected area immediately with plenty of water.
Continue decontamination with polyethylene glycol 400 after initial rinsing with water and then wash with water and soap.
If symptoms persist, consult a physician for treatment.

Eye contact:
With eye held open, thoroughly rinse immediately with plenty of water for at least 10 minutes.
Consult an ophthalmologist immediately if the symptoms persist.

Ingestion:
Rinse mouth.
Immediately give large quantities of water to drink.
Obtain medical attention.

Most important symptoms and effects, both acute and delayed

Symptoms:
Irritation of skin and mucous membranes

Hazards:
irritant effects

Indication of any immediate medical attention and special treatment needed
The initial focus is only on the local action, possibly characterized by a progressive tissue irritation.
Coughing is a symptom of a respiratory tract irritation after inhalation of aerosols or mists from caustic liquids.
In the eye, irritating liquids cause, depending on the intensity of exposure, irritation of the conjunctiva and, in exceptional cases, damage to the cornea.
There is a danger of blindness if corneas are damaged!
Superficial irritations and only infrequent damage with ulcerations develop on the skin.
An irritation of the mucous membranes may develop and lead to coughing after inhalation.

Fire-fighting measures

Extinguishing media

Suitable extinguishing media: Water spray, foam, CO2, dry powder.
Unsuitable extinguishing media: high volume water jet

Special hazards arising from the substance or mixture:
Hazardous fumes in fires, specific to the product:
hydrochloric acid
Under certain fire conditions, traces of other toxic products may occur

Advice for firefighters:
Water for fire fighting must not be introduced in the sewer system, subsoil, or surface waters. Assure that there are sufficient fire water retaining facilities Contaminated fire fighting water must be disposed of in conformity with the regulations of the local authorities.
In case of fire, remove the endangered barrels and bring to a safe place, if this can be done safely.
Use water spray to cool unopened containers.
Fire residues should be disposed of in accordance with the regulations.
Wear suitable protective clothing.
wear a self contained respiratory apparatus

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Avoid contact with skin.
Keep unauthorized persons away

Environmental precautions
Observe regulations on prevention of water pollution (check, dam up, cover up).
Do not allow entrance in sewage water, soil, stretches of water, drainage systems, surface water.
If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and material for containment and cleaning up
Pick up with suitable adsorbent material.
Suitable binder: vermiculite, universal absorbent, dry sand
Transfer into suitable containers.
Clean contaminated surface thoroughly.
Pack and label wastes like the pure substance. Do not detach label from the delivery containers prior to disposal.
Disposal according to local authority regulations.

Additional advice:
Dispose of contaminated material as a waste in a correct manner.

Handling and storage

Precautions for safe handling
Use permissible in closed systems only. Handle and transfer product in closed systems only (gas displacement device).
Ensure that apparatus and pipelines are free from leaks. Do not ventilate into the open.
Suitable loading and unloading device required.
Empty, clean and dry system / system components completely before maintenance and repair work is done.
Written approval necessary in case of non-routine jobs, e.g. maintenance activities.

Conditions for safe storage, including any incompatibilities

Advice on protection against fire and explosion:
No special measures are required.

Storage:
Store in the original receptacle, keeping this tightly sealed, under cool and dry conditions.
Suitable materials stainless steel
Unsuitable materials Light metals, copper, brass and their alloys
Do not store together with: strong acids, bases.

Further information:
In order to ensure due transportation, make certain that stacks are of the correct height, containers are securely fastened so as not to fall off, and labelled according to the regulations.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN 3082
Shippingopen allclose all
Labels:
9
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
UN 3082
Shippingopen allclose all
Labels:
9
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN 3082
Shipping information
Proper shipping name and description:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (1-chlorododecane)
Chemical name:
(1-chlorododecane)
Labels:
9
Marine pollutant
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN 3082
Shipping information
Proper shipping name and description:
Environmentally hazardous substance, liquid, n.o.s. (1-chlorododecane)
Chemical name:
(1-chlorododecane)
Labels:
9
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters:

• 1-chlorodecane
CAS-No: 1002-69-3
EC-No.: 213-691-0
Control parameters: (DFG MAK) Included in the regulation but with no data values. See regulation for further details

Exposure controls:

Engineering measures:

Refill and handle product only in closed system.
Leak detection recommended
Minimization of emissions by means of suitable technical measures such as flanges and valves with low leakage rates, recirculation of vapours.
All precautionary measures indicated have to be observed.

Exposure controls:
The substance must be handled under strictly controlled conditions in accordance with Article 17/18 of the REACH regulation.
Personal protective equipment

Respiratory protection:
Use suitable respiratory protection where aerosols/vapours are generated.
use respiratory equipment with suitable filter (combined filter A-P2) or wear a self contained respiratory apparatus
Note time limit for wearing respiratory protective equipment.

Hand protection:
Glove material Nitrile, for example:, Camatril 731
Material thickness 0.33 mm
Method DIN EN 374
Accidental release measures
Glove material Nitrile, for example:, Camatril (730)
Material thickness 0.4 mm
Method DIN EN 374

Eye protection:
Safety glasses with side-shields conforming to EN166

Skin and body protection:
suitable protective clothing - Use disposable clothing if appropriate.

Hygiene measures:
Take off clothing and shoes contaminated with product. Clean before reuse.
Avoid contact with skin.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
Do not eat, drink, smoke, or sniff while at work. Wash your hands and/or face before breaks and before termination of work.

Protective measures:
The personal protective equipment used must meet the requirements of directive 89/686/EEC and amendments (CE certification).
All precautionary measures indicated have to be observed.
Risk assessment and risk monitoring of all work places required.
Health, Safety and Emergency Management System recommended.
Regular safety training is a must.
Written approval necessary in case of non-routine jobs, e.g. maintenance activities

Stability and reactivity

Possibility of hazardous reactions: No

Incompatible materials: Strong acids and strong bases.

Hazardous decomposition products: Decomposition products in combustion, chemical or thermal decomposition hydrogen chloride.

Disposal considerations

Product:
Strictly controlled conditions during disposal or treatment to air, wastewater and waste.
Bring wastewater containing AOX for professional disposal.
Disposal according to local authority regulations.
Pack and label wastes like the pure substance. Do not detach label from the delivery containers prior to disposal.

Uncleaned packaging:
Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.

Waste Key Number:
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the
disposal firm / producing firm / official authority.