Description of key information

Reaction mass of cerium dioxide and lanthanum oxide and lanthanum fluoride presents D10, D50 and D90 equal to 4.47 µm, 11.775 µm and 37.153 µm, respectively.

Additional information

A GLP-compliant study of reliability 1 according to Klimisch was available on the reaction mass (Demangel, 2010). It was flagged as a key study. As granulometry is a substance-specific parameter, the particle size distributions of the constituents were not reported here.