Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25JAN2010 - 05FEB2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method closed cup
Key result
Flash point:
225 °C
Atm. press.:
1 013 mBar
Remarks on result:
other: A pre-test indicated a flashpoint for the test item of 226.5 degrees C, at 1026 hPa. No duplicate measurements have been indicated in the test report.
Interpretation of results:
other: not a flammable liquid according to the CLP Regulation
Conclusions:
The flash point of the tested substance was determined to be 225 °C at 1013 mbar, using a rapid equilibrium closed cup method (in accordance with DIN EN ISO 3679). Because the flash point is > 60°C, the test substance is not a flammable liquid according to the CLP Regulation.

Description of key information

The flash point of the substance was determined to be 225 °C at 1013 mbar.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
225 °C

Additional information

Determined in a study performed in accordance with ISO 3679, using a rapid equilibrium closed cup method.

Based on this result the substance is considered 'not a flammable liquid' according to the CLP Regulation.