Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14 -15 April 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Version / remarks:
(1984)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Analytical monitoring:
not required
Vehicle:
no
Details on test solutions:
The test substance was directly weighed out in each test vessel. After 24h of stirring the test substance was completely dispersed.
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
- Origin: Municipal sewage treatment plant of D-31157, Sarstedt Germany
- Preparation of inoculum for exposure:
- Pretreatment: The sludge was washed twice with autoclaved tap water and adjusted corresponding to a dry weight of 4.0 g/L ± 10%. The sludge was used within 24 h after sampling.
- Dry sludge concentration: 3.97 g/L
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Hardness:
Not reported
Test temperature:
20.9 °C
pH:
6.89
Dissolved oxygen:
5.2 - 7.7 mg O2/L (determined at the start of the measurement)
Nominal and measured concentrations:
Nominal concentrations: 0 (control), 100, 180, 320, 580 and 1000 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel: 500 mL Erlenmeyer flasks
- Aeration: Permanent
- No. of vessels per concentration (replicates): 1
- No. of vessels per control (replicates): 2

TEST MEDIUM / WATER PARAMETERS
Composition of the test medium:
200 mL inoculum
16 mL synthetic waste water
284 mL autoclaved tap water
test item concentration (directly weighed out in each test vessel)


EFFECT PARAMETERS MEASURED:
The oxygen depletion of the control, reference and test item replicates was measured after 3 hours incubation by means of an oximeter and recorded for at least 3 minutes on a flat bed recorder.

TEST CONCENTRATIONS
- Spacing factor for test concentrations: 1.8
- Range finding study: Yes
- Test concentrations: 0 (control), 10, 100 and 1000 mg/L
- Results used to determine the conditions for the definitive study: 0% inhibition at 10 mg/L, 4% inhibtion at 100 mg/L and 18% at 1000 mg/L
Reference substance (positive control):
yes
Remarks:
copper (II) sulphate pentahydrate
Key result
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Details on results:
The EC10 is estimated by the reviewer to be 1000 g/L (11% inhibition at 1000 mg/L and 9% inhibition at 580 mg/L).
Results with reference substance (positive control):
The 3h-EC50 of the refence substance copper (II) sulphate pentahydrate was 103 mg/L which is within the recommended confidence range of 54 - 156 mg/L

Table: Respiration rates and inhibition of respiration of test and reference item concentrations.

Treatment

Concentration (mg/L)

Respiration rate (mg O2/L/h)

Inhibition (%)

Test item

1000

28.0

11

580

28.8

9

320

31.6

0

180

30.0

5

100

32.8

-4

Control

-

31.2

-

-

32.0

-

Reference item

180

9.2

71

100

14.8

53

58

23.6

25

 

Validity criteria fulfilled:
yes
Remarks:
The two control respiration rates differ not more than 15% in the study. The 3h-EC50 of copper (II) sulphate pentahydrate is within the accepted range of 54-156 mg/L.
Conclusions:
The 3h-EC50 of the test substance to activated sludge was > 1000 mg/L
The 3h-EC10 of the test substance to activated sludge, estimated by the reviewer was 1000 mg/L
Executive summary:

The toxicity of the test substance to activated sludge was investigated according to OECD guideline 209 and GLP.

The 3h-EC50 of the test substance to activated sludge was > 1000 mg/L

The 3h-EC10 of the test substance to activated sludge, estimated by the reviewer (based on 11% inhibition at 1000 mg/L and 9 % inhibition at 580 mg/L) was ca. 1000 mg/L.

Because the test was carried out according to OECD209 and GLP an no shortcomings were observed a reliability 1 was assigned.

Description of key information

The 3h-EC50 of the test substance to activated sludge was > 1000 mg/L.
The 3h-EC10 of the test substance to activated sludge, estimated by the reviewer was 1000 mg/L.

Key value for chemical safety assessment

EC50 for microorganisms:
1 000 mg/L

Additional information

The toxicity of the test substance to activated sludge was investigated according to OECD guideline 209 and GLP.

The 3h-EC50 of the test substance to activated sludge was > 1000 mg/L.

The 3h-EC10 of the test substance to activated sludge, estimated by the reviewer (based on 11% inhibition at 1000 mg/L and 9 % inhibition at 580 mg/L) was ca. 1000 mg/L. Based on the fact that this is an estimation, the worst-case EC50 value of 1000 mg/L is taken as key value for the CSA.

Since the test was carried out according to OECD209 and GLP, and because no shortcomings were observed a reliability 1 was assigned.