Measures indicated are for the substance at ~50-70% concentration in mineral oil, as marketed.

General advice : No hazards which require special first aid measures.

If inhaled : Move to fresh air in case of accidental inhalation of dust or fumes from overheating or combustion.

If symptoms persist, call a physician.

In case of skin contact : Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water.

In case of burns apply cold water until pain subsides then seek medical advice.

In case of eye contact : Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing.

If swallowed : Clean mouth with water and drink afterwards plenty of water.

Do not give milk or alcoholic beverages.

Never give anything by mouth to an unconscious person.

Most important symptoms and effects, both acute and delayed : No symptoms known or expected.

Indication of any immediate medical attention and special treatment needed : No hazards which require special first aid measures.

Do not induce vomiting: contains petroleum distillates and/or aromatic solvents. Keep patient warm and at rest.

Fire-fighting measures

Measures indicated are for the substance at ~50-70% concentration in mineral oil, as marketed.

Suitable extinguishing media : Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames

Unsuitable extinguishing media : Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Special hazards arising from the substance or mixture

Combustibility : Combustible.

Hazardous combustion products : Phosphorus oxides, Sulphur oxides, Carbon monoxide, carbon dioxide and unburned hydrocarbons (smoke).

Flammable properties : See information on flammability.

Advice for firefighters

Protective equipment and precautions for firefighters : In the event of fire, wear self-contained breathing apparatus.

Fire Fighting Instructions : Collect contaminated fire extinguishing water separately. This must not be discharged into drains.

Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Accidental release measures

Measures indicated are for the substance at ~50-70% concentration in mineral oil, as marketed.

Personal precautions :

Advice for emergency responders: Use personal protective equipment.

Advice for non-emergency personnel: Avoid contact with spilled material. Do not touch or walk through spilled material.

Keep people away from and upwind of spill/leak.

Environmental precautions : No Exposure Scenario annex is attached to this safety data sheet as it is a non-classified mixture containing no

hazardous substances.

Prevent entry into waterways, sewers, basements or confined areas.

Do not flush into surface water or sanitary sewer system.

Methods for cleaning up : Prevent further leakage or spillage if safe to do so.

Large Spills: Dyke far ahead of liquid spill for later recovery

and disposal.

Recover by pumping or with suitable absorbent

Report spills as required to appropriate authorities.

Seek the advice of a specialist before using dispersants.

Dispose of according to local regulations.

In the event of a spill or accidental release, notify relevant

authorities in accordance with all applicable regulations.

Material will sink to the sediment layer

Remove debris in path of spill prior to oiling and remove contaminated debris from shoreline and water surface.

Wipe up with absorbent material (e.g. cloth, fleece).

Keep in suitable, closed containers for disposal.

Handling and storage

Measures indicated are for the substance at ~50-70% concentration in mineral oil, as marketed.

Dispose of rinse water in accordance with local and national regulations.

Normal measures for preventive fire protection.

Products may load from Infineum manufacturing site above the standard loading/unloading range.

Loading/unloading temperature : 50 °C (122 ° F) - 60 °C (140 ° F)

Viscosity @ Loading/unloading temperature : 311 cSt - 773 cSt

Static accumulator : This material is not a static accumulator.

Conditions for safe storage, including any incompatibilities

Keep container tightly closed in a dry and well-ventilated place.

Containers which are opened must be carefully resealed and kept upright to prevent leakage.

No decomposition if stored and applied as directed.

Do not reheat above: 60 °C (140 ° F)

Storage temperature : <= 60 °C (140 ° F)

Incompatible materials and coatings : butyl-rubber

Specific use(s) : This material should not be used for any other purpose than that recommended without expert advice.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not regulated for transport by land
Shippingopen allclose all
Labels:
Not regulated for transport by land
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not regulated for transport by sea under IMDG code
Shipping information
Proper shipping name and description:
Not regulated for transport by sea under IMDG code
Labels:
Not regulated for transport by sea under IMDG code
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not regulated for transport by air
Shipping information
Proper shipping name and description:
Not regulated for transport by air
Labels:
Not regulated for transport by air
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Measures indicated are for the substance at ~50-70% concentration in mineral oil, as marketed.

Control parameters

Exposure limits for materials that can be formed when handling this product: When mists/aerosols can occur, the following are recommended:

5mg/m³ - ACGIH TLV, 10 mg/m³ - ACGIH STEL

Limits/standards shown for guidance only. Follow applicable regulations.

Recommended monitoring procedures : This product contains ingredients with exposure limits, personal, workplace atmosphere or biological monitoring may be required to determine the effectiveness of the ventilation or other control measures and/or the necessity to use respiratory protective

equipment.

Reference should be made to European Standard EN 689 for methods for the assessment of exposure by inhalation to chemical agents and national

guidance documents for methods for the determination of hazardous substances.

Exposure controls

Appropriate engineering controls : No Exposure Scenario annex is attached to this safety data sheet as it is a non-classified mixture containing no

hazardous substances.

No special requirements under ordinary conditions of use and with adequate ventilation.

Personal protective equipment Respiratory protection : No personal respiratory protective equipment normally required.

The applicable European standard can be found in EN 14605.

Hand protection Remarks : For prolonged or repeated contact use protective gloves.

Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into

consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. When

handling hot material, use heat resistant gloves.

Eye/face protection : Safety glasses

The applicable European standard can be found in EN 166.

Skin and body protection : Protective suit Long sleeved clothing

The applicable European standard can be found in EN 140, EN 137, EN 143, EN 14387.

Advice on general occupational hygiene Hygiene measures : General industrial hygiene practice.

Environmental exposure controls

General advice : No Exposure Scenario annex is attached to this safety data sheet as it is a non-classified mixture containing no hazardous

substances.

Prevent entry into waterways, sewers, basements or confined areas.

Do not flush into surface water or sanitary sewer system.

Stability and reactivity

Measures indicated are for the substance at ~50-70% concentration in mineral oil, as marketed.

Reactivity: No dangerous reaction known under conditions of normal use.

Chemical stability: Stable under recommended storage conditions.

Possibility of hazardous reactions : No hazards to be specially mentioned.

Conditions to avoid : Elevated temperatures. Open flames and high energy ignition sources.

Incompatible materials : Strong oxidizing agents

Hazardous decomposition products : No decomposition if used as directed.

Disposal considerations

Measures indicated are for the substance at ~50-70% concentration in mineral oil, as marketed.

Waste treatment methods Product : Dispose of contents/ container to an approved waste disposal plant.

Disposal recommendations based on material as supplied, Disposal must be in accordance with applicable laws and regulations, and material characteristics at time of disposal

For the safety of persons conducting disposal, recycling or reclamation activities, refer to the information in Section 8, Exposure control and

personal protection.

Empty Container Warning (where applicable): Empty containers may contain residue and can be dangerous. Do not attempt to refill or clean containers without proper instructions. Empty drums should be completely drained and safely stored until appropriately reconditioned or disposed.

Empty containers should be taken for recycling, recovery, or disposal through suitably qualified or licensed contractor and in accordance with governmental regulations. DO NOT PRESSURISE,  CUT, WELD, BRAZE, SOLDER, DRILL, GRIND, OR EXPOSE SUCH CONTAINERS TO HEAT, FLAME, SPARKS,

STATIC ELECTRICITY, OR OTHER SOURCES OF IGNITION. THEY MAY EXPLODE AND CAUSE INJURY OR DEATH.

Regulatory disposal information

European Waste Code : 13 02 XX

waste engine, gear and lubricating oils