Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): MEOE
- Analytical purity: 95 %
Dynamic viscosity of test material:
The viscosity does not need to be performed as the substance is a solid.

Results and discussion

Density
Key result
Type:
relative density
Density:
1.24 other: dimensionless
Temp.:
20 °C

Any other information on results incl. tables

Results

Density determination of the displacement liquid:

The density was determined using the oscillating density meter.

1st determination: 0.7939 g/cm3

2nd determination: 0.7939 g/cm3

The measurements were carried out at 20°C

Density determination of the test item

 

2nddet.

3rddet.

Mass of pycnometer empty(corrected for air)[g]

37.5972

38.1885

Mass of pycnometer with test item(corrected for air)[g]

41.6866

43.3813

Mass of pycnometer with test item and displacement liquid [g]

57.4911

59.8634

Mass of displacement liquid calculated for the total pycnometer volume[g]

18.4161

19.7935

Mass of test item (B - A)[g]

4.0895

5.1928

Mass of displacement liquid (C-B)[g]

15.8045

16.4821

Mass of displacement liquid calculated for the volume taken by the test item (D - F)[g]

2.6116

3.3114

Density of the test item (E/G density of displacement liquid)[g/cm3]

1.243

1.2450

Relative density d420(H/density of water at 4 °C) (mean)

1.244

volume of 1st pycnometer: 23.197 cm3 ; volume of 2nd pycnometer: 24.932 cm3

Masses are Iisted in gram.

Measuring temperature = 20°C

The relative density was calculated by division of the density of test item at 20°C and the density of water at 4°C.

Applicant's summary and conclusion