Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
03/AUG/04 - 19/NOV/04
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes
Type of method:
static method
Specific details on test material used for the study:
Asahiklin AE-3000, molecular weight 200.07
CAS 406-78-0
Clear colourless liquid
Batch 50407070
Purity: 99.985%
The test substance was stored in a refrigerator in the dark under stable conditions
The test substance expiry date was the 07 July 2005
Key result
Temp.:
20 °C
Vapour pressure:
30.78 kPa

The measured vapour pressures are their natural logarithms are summarised below and are expressed in kPa. The values given are rounded values:

36.92°C (310.07 K)

30.49°C (303.64 K)

23.31°C (296.46 K)

 nr

p/kPa

Ln (p/Pa)

 nr

p/kPa

Ln (p/Pa)

 nr

p/kPa

Ln (p/Pa)

1*

58.86

10.98

15

46.14

10.74

24*

35.42

10.48

2*

58.61

10.98

16

46.13

10.74

25

35.27

10.47

3

58.39

10.97

17

46.14

10.74

26

35.13

10.47

4

58.29

10.97

18

46.08

10.74

27

35.06

10.46

5

58.17

10.97

19

46.10

10.74

28

34.96

10.46

6

58.11

10.97

20

46.15

10.74

29

34.90

10.46

7

58.06

10.97

21

46.10

10.74

30

34.92

10.46

8

58.03

10.97

22

46.08

10.74

31

34.90

10.46

9

57.99

10.97

23

46.07

10.74

 

 

 

10

57.91

10.97

 

 

 

 

 

 

11

57.9

10.97

 

 

 

 

 

 

12

57.87

10.97

 

 

 

 

 

 

13

57.85

10.97

 

 

 

 

 

 

14

57.83

10.97

 

 

 

 

 

 

 * System instability - measurement not used for calculation

Vapour pressure of 1,1,2,2-tetrafluoroethyl-2,2,2-trifluoroethyl ether at 3 different temperatures:

Measurement

Temperature

Mean vapour pressure±2 x calculated error [pa]

[°C]

[K]

p

ln p

3-14

36.92

310.07

58033 ± 286

10.969 ± 0.005

15-23

30.49

303.64

46111 ± 51

10.739 ± 0.001

25-31

23.31

296.46

35020 ± 227

10.464 ± 0.006

 

Fitting these data using the least squares method gave a value of 30.78kPa for the vapour pressure of the test substance at 20°C.

Conclusions:
The vapour pressure for 1,1,2,2-tetrafluoroethyl-2,2,2-trifluoroethyl ether was determined as:

p (20°C) = 30.8 ± 0.4kPa = 231 ± 3 mmHg
Executive summary:

An experiment was carried out to determine the vapour pressure of 1,1,2,2-tetrafluoroethyl-2,2,2-trifluoroethyl ether using the static technique.

A total of 31 measurements were made with a capacitance manometer, at temperatures of 36.92°C, 30.49°C and 23.31°C respectively. Fitting of the data obtained using the least squares method gave a value of p (20°C) = 30.8 ± 0.4kPa = 231 ± 3 mmHg for the vapour pressure of 1,1,2,2-tetrafluoroethyl-2,2,2-trifluoroethyl ether

Description of key information

Key value for chemical safety assessment

Vapour pressure:
30.78 kPa
at the temperature of:
20 °C

Additional information