Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant, guideline study, available as unpublished report, no restrictions, fully adequate for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
yes (incl. QA statement)
Remarks:
Competence Center Analytics , BASF SE, D-67056 Ludwigshafen
Type of method:
thermal analysis

Test material

Constituent 1
Chemical structure
Reference substance name:
3-[(2-hydroxyethyl)amino]propanol
EC Number:
242-978-3
EC Name:
3-[(2-hydroxyethyl)amino]propanol
Cas Number:
19344-29-7
Molecular formula:
C5H13NO2
IUPAC Name:
3-[(2-hydroxyethyl)amino]propan-1-ol
Details on test material:
- Name of test material (as cited in study report): 3-(2-Hydroxyethylamino)-1-propanol
- Physical state: liquid
- Analytical purity: 99.2 g/100 g (1H-NMR); 98.9 g/100 g (titration)
- Lot/batch No.: 74568175L0
- Storage condition of test material: Room temperature

Results and discussion

Melting / freezing point
Atm. press.:
1 013 hPa
Decomposition:
no
Remarks on result:
other: The test item had no melting temperature between -100 °C and 50 °C. A glass transition was found at -76 °C.

Any other information on results incl. tables

Melting temperature: No melting temperature was found between -100 °C and 50 °C, even by addition of aluminum oxide powder as crystallization aid (Test 1 and 2) and annealing at -40 °C (Test 2). A reproducible glass transition was found at -76 °C in the 1st heating (determination A and B).

determination

glass transition temperature [°C]

A

-75.5

B

-75.6

Mean value

-76

The estimated accuracy is ± 1 °C.

Observed thermic processes: No other thermic process was found.

In order to survey the thermic behavior of the test item a preliminary TG/DTA-Test (non-GLP) was run up to 600 °C. An endothermic peak starting at about 150 °C with a total weight loss at 250 °C showed the vaporization of the test item.

 

Applicant's summary and conclusion