Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant, guideline study, available as unpublished report, no restrictions, fully adequate for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Qualifier:
according to guideline
Guideline:
other: The determination of the density was carried out according to the OECD Guideline for the Testing of Chemicals 109
GLP compliance:
yes (incl. QA statement)
Remarks:
Competence Center Analytics , BASF SE, D-67056 Ludwigshafen
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Chemical structure
Reference substance name:
3-[(2-hydroxyethyl)amino]propanol
EC Number:
242-978-3
EC Name:
3-[(2-hydroxyethyl)amino]propanol
Cas Number:
19344-29-7
Molecular formula:
C5H13NO2
IUPAC Name:
3-[(2-hydroxyethyl)amino]propan-1-ol
Details on test material:
- Name of test material (as cited in study report):3-(2-Hydroxyethylamino)-1-propanol
- Physical state: liquid
- Analytical purity: 99.2 g/100 g (1H-NMR); 98.9 g/100 g (titration)
- Lot/batch No.: 74568175L0
- Storage condition of test material: Room temperature

Results and discussion

Viscosityopen allclose all
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1 010
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
1 080
Remarks on result:
other: calculated with a density of the test item of p = 1.0669 g/mL
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
232
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
245
Remarks on result:
other: calculated with a density of the test item of p = 1.0534 g/mL

Applicant's summary and conclusion