Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-01-12
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)
Specific details on test material used for the study:
Batch No: 5820146
Purity: 99.99%
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.675
Remarks on result:
other: mean viscosity value of 5 test results
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.564
Remarks on result:
other: mean viscosity value of 5 test results
Conclusions:
Based on the results, the mean viscosity value of 5 test results was 0.6746 mm2/s at 20°C, the relative standard deviation (RSD %, n=5) was 0.00%. And the mean viscosity value of 5 test results was 0.5637 mm2/s at 40°C, the relative standard deviation (RSD %, n=5) was 0.35%.
Executive summary:

The viscosity of test item was measured by kinematic viscometer according to OECD 114. Ф0.4 mm viscometer was selected and the test temperature was set at 20 °C and 40 °C separately.

Based on the results, the mean viscosity value of 5 test results was 0.6746 mm2/s at 20°C, the relative standard deviation (RSD %, n=5) was 0.00%. And the mean viscosity value of 5 test results was 0.5637 mm2/s at 40°C, the relative standard deviation (RSD %, n=5) was 0.35%.

Description of key information

The mean viscosity value was 0.6746 mm2/s at 20°C, the mean viscosity value was 0.5637 mm2/s at 40°C.

Key value for chemical safety assessment

Viscosity:
0.675 mm²/s (static)
at the temperature of:
20 °C

Additional information

The viscosity of test item was measured by kinematic viscometer according to OECD 114. Ф0.4 mm viscometer was selected and the test temperature was set at 20 °Cand 40 °Cseparately.

Based on the results, the mean viscosity value of 5 test results was 0.6746 mm2/s at 20°C, the relative standard deviation (RSD %, n=5) was 0.00%. And the mean viscosity value of 5 test results was 0.5637 mm2/s at 40°C, the relative standard deviation (RSD %, n=5) was 0.35%.