Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2004-04-21 to 2004-06-23
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004
Report date:
2004

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
air comparison pycnometer (for solids)

Test material

Constituent 1
Chemical structure
Reference substance name:
1,5-dimethyl 3-methyl-9-oxo-2,4-bis(pyridin-2-yl)-7-[(pyridin-2-yl)methyl]-3,7-diazabicyclo[3.3.1]nonane-1,5-dicarboxylate dichloroiron hydrate
EC Number:
610-388-9
Cas Number:
478945-46-9
Molecular formula:
C28H31N5O6FeCl2
IUPAC Name:
1,5-dimethyl 3-methyl-9-oxo-2,4-bis(pyridin-2-yl)-7-[(pyridin-2-yl)methyl]-3,7-diazabicyclo[3.3.1]nonane-1,5-dicarboxylate dichloroiron hydrate
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: S2539801
- Expiration date of the lot/batch:
- Purity test date: 2004-11-12

RADIOLABELLING INFORMATION (if applicable) no

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
ambient/dark

TREATMENT OF TEST MATERIAL PRIOR TO TESTING: no

Results and discussion

Density
Key result
Type:
relative density
Density:
1.52
Temp.:
20.5 °C

Any other information on results incl. tables

Calibration:

The pressure readings (P1 and P2) and the calculated volume for the calibration ball are:

A: P1=17.004, P2=8.418, Volume=56.5 cm3, certified volume: 56.6 cm3, tolerance=+/-0.5 cm3

B: P1=17.307, P2=8.568, Volume=56.5 cm3, certified volume: 56.6 cm3, tolerance=+/-0.5 cm3

Sample:

The pressure readings, calculated volumes and density values for the test material are:

A: P1=16.995, P2=6.985, Volume=56.5 cm3, Volume: 18.883 cm3, density=1523.9 Kg/m3

B: P1=17.098, P2=6.990, Volume=56.5 cm3, Volume: 17.701 cm3, density=1523.3 Kg/m3

Temperature: 20.5 +/-0.5°C

Mean density: 1523.6 Kg/m3

Relative density: 1.52

Applicant's summary and conclusion

Conclusions:
The relative density of the test material has been determined to be 1.52 at 20.5+/-0.5°C
Executive summary:

The purpose of the test was to determine the relative density of the test item, according to the A3 method and following GLP. A gas comparison pycnometer was used. The relative density of the test material has been determined to be 1.52 at 20.5+/-0.5°C.