Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 219-702-5 | CAS number: 2500-88-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Basic toxicokinetics
Administrative data
- Endpoint:
- basic toxicokinetics
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- April - May 2005
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: Scientific sound study design with restricted reporting.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 012
- Report date:
- 2012
Materials and methods
- Objective of study:
- absorption
- distribution
- excretion
Test guideline
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 417 (Toxicokinetics)
- Deviations:
- no
- GLP compliance:
- not specified
Test material
- Reference substance name:
- Dioctadecyldisulfide
- IUPAC Name:
- Dioctadecyldisulfide
- Reference substance name:
- Hostanox SE 10
- IUPAC Name:
- Hostanox SE 10
- Test material form:
- not specified
- Details on test material:
- no data
Constituent 1
Constituent 2
- Radiolabelling:
- no
Test animals
- Species:
- rat
- Strain:
- Wistar
- Sex:
- male
- Details on test animals or test system and environmental conditions:
- TEST ANIMALS
- Individual metabolism cages: yes
- Acclimation period: 4 days
Administration / exposure
- Route of administration:
- oral: gavage
- Vehicle:
- corn oil
- Details on exposure:
- Male Wistar rats were administered single oral doses of 100 and 1000 mg/kg bw Hostanox SE 10, dissolved in corn oil (1 mL). After administration, animals were transferred to metabolic cages to collect urine and feces for up to 96 h.
- Duration and frequency of treatment / exposure:
- single application
Doses / concentrations
- Remarks:
- Doses / Concentrations:
100 or 1000 mg/kg bw
- No. of animals per sex per dose / concentration:
- no data
- Control animals:
- no
- Positive control reference chemical:
- none
- Details on study design:
- Male Wistar rats were administered single oral doses of 100 and 1000 mg/kg bw Hostanox SE 10, dissolved in corn oil (1 mL). After administration, animals were transferred to metabolic cages to collect urine and feces for up to 96 h. To collect blood and organs, treated animals were sacrificed at 3, 6, 12, 24, 48, 72 and 96h.
- Details on dosing and sampling:
- Blood, urine and feces samples and organs were immediately frozen and kept at -20°C for analysis. To determine Hostanox SE 10 content, feces samples were lyophilized and the obtained residues were extracted with n-Pentane in a Soxhlett-extractor. The Pentane extracts were further purified using chromatography on silica gel cartridges. Hostanox SE 10 content was then quantified in the eluate from the silica gel purification step by GC/MS. Hostanox SE 10 concentrations were determined relative to the internal standard. Blood samples (150 - 500 µL) and organ homogenates (150 - 500 mg) were boiled for 15 min. after acidification with HCl. After 15 min. at 100 °C, the obtained samples were cooled to room temperature and extracted with Pentane. The Pentane phase was than purified by passing through a silica gel column. In the obtained eluate, Hostanox SE 10 was quantified by GC/MS.
- Statistics:
- none
Results and discussion
- Preliminary studies:
- none
Main ADME resultsopen allclose all
- Type:
- absorption
- Results:
- poor absorption since 93+/-14% of the applied amount was found in feces within 72 h
- Type:
- distribution
- Results:
- low concentrations observed in liver, kidney and mesentheric lymphnodes
- Type:
- excretion
- Results:
- major elimination pathway is with feces as unchanged parent compound
Toxicokinetic / pharmacokinetic studies
- Details on absorption:
- After oral administration of Hostanox SE 10 in single doses of 100 and 1000 mg/kg bw, detectable concentrations of Hostanox SE 10 in blood were observed aftter 3 h and peaked in the high dose at the 6 h sampling point. After 6 h, the blood levels of Hostanox SE 10 decreased to reach the limit of detection 24 h after administration of 100 mg/kg bw.
In animals administered 1000 mg/kg bw, Hostanox SE 10 was still detectable in blood 96 h after administration.
In general, the blood levels of Hostanox SE 10 were low and peaked at 250 pmol/mL blood even after application of the high dose of 1000 mg/kg bw.
Most of the administered dose (93 +/- 14 %) was recovered in feces within 72 h indicating poor absorption of Hostanox SE 10 from the gastro-intestinal tract and no or very limited metabolism.
Administration of hostanox SE 10 also caused a dose- and time-dependent increase of the test item mesentheric lymphnodes, liver and kidneys. However, organ levels were below 1.2 nmol/g organ and therefore very low, even after administration of the high dose. - Details on distribution in tissues:
- Administration of hostanox SE 10 also caused a dose- and time-dependent increase of the test item mesentheric lymphnodes, liver and kidneys. However, organ levels were below 1.2 nmol/g organ and therefore very low, even after administration of the high dose.
- Details on excretion:
- The elimination of Hostanox SE 10 after the high dose followed first-order kinetics with an apparent half-life of 14 h. In all urine samples, the concentration of Hostanox SE 10 was below the limit of detection. Most of the administered dose (93 +/- 14%) was recovered in feces within 72 h.
Toxicokinetic parameters
- Test no.:
- #1
- Toxicokinetic parameters:
- half-life 1st: 14 h
Metabolite characterisation studies
- Metabolites identified:
- not measured
- Details on metabolites:
- n.a.
Bioaccessibility (or Bioavailability)
- Bioaccessibility (or Bioavailability) testing results:
- Most of the administered dose (93 +/- 14%) was recovered in feces within 72 h indicating a very limited bioaccessibility.
Applicant's summary and conclusion
- Conclusions:
- Interpretation of results (migrated information): no bioaccumulation potential based on study results
Hsotanox SE 10 absorption from gastro-intestinal tract is very limited after oral administration. The blood concentration peak is at 6 h after application. The elimination of Hostanox SE 10 follows first-order kinetics with an apparent half-life of 14 h. Most of the administered dose (93 +/- 14 %) is excreted via feces indicating a very low bioaccessibility. Concentration level in mesentheric lymphnodes, liver and kidney is below 1.2 pmol/o organ. - Executive summary:
The dispositon of Hostanox SE 10 was investigated in male Wistar rats after single oral doses of 100 and 1000 mg/kg bw. A dose-dependent increase in blood concentration of Hostanox SE 10 was observed and Hostanox SE 10 was cleared from blood within a parent half-life of 14 hours. Maximum blood concentrations of Hostanox SE 10 were reached within 6 hours and were 250 pmol/mL blood. Low concentrations of the test item were also observed in liver, kidney and mesentheric lymphnodes. The data indicate that Hostanox SE 10 absorption from the gastro-intestinal tract is very limited after oral administration and that the absorbed amount of the substance is rapidly cleared from blood. Most of the administered dose (93 +/- 14 %) was recovered in feces within 72 h supporting the observed low bioaccessibility.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.