Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22.03.2021-25.03.2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Remarks on result:
no self ignition observed under the test conditions

Graph 1. Result of determination of relative self-ignition temperature (see in Illustration subsection)

Conclusions:
The test item does not have a relative self-ignition temperature up to 400ºC according to the EU A.16 method criteria.
Executive summary:

The determination of the relative self-ignition temperature of the test item was performed in accordance to EU A.16 guidelines, under GLP conditions. After conducting the main test, it was determined that the test item does not have a relative self-ignition temperature up to 400ºC.

Description of key information

Key study. Method according to EU A.16 guidelines, GLP study. After conducting the main test, it was determined that the test item does not have a relative self-ignition temperature up to 400ºC.

Key value for chemical safety assessment

Additional information

The determination of the relative self-ignition temperature of the test item was performed in accordance to EU A.16 guidelines, under GLP conditions. After conducting the main test, it was determined that the test item does not have a relative self-ignition temperature.