Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17/08/2017-18/08/2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Benzyldodecyldimethylammonium bromide
EC Number:
230-698-4
EC Name:
Benzyldodecyldimethylammonium bromide
Cas Number:
7281-04-1
Molecular formula:
C21H38N.Br
IUPAC Name:
N-benzyl-N,N-dimethyldodecan-1-aminium bromide
Constituent 2
Chemical structure
Reference substance name:
benzyltetradecyldimethylammonium bromide
Cas Number:
18773-88-1
Molecular formula:
C23H42N.Br
IUPAC Name:
benzyltetradecyldimethylammonium bromide
Test material form:
liquid: viscous
Details on test material:
Colour : yellow
Specific details on test material used for the study:
Product name : Axenyl BR12
Batch number : 91602E004
CTL sample reference : 400006168
Appearance : As received, the sample is observed to be a yellow viscous liquid
Preparation : Sample tested as received

Study design

Contact with:
powdered cellulose
Duration of test (contact time):
< 10 min

Results and discussion

Test results (Oxidising liquids)open allclose all
Key result
Sample tested:
test mixture 1:1
Parameter:
mean pressure rise time
Result:
ca. 41.859 s
Key result
Sample tested:
reference mixture 1: 1
Parameter:
mean pressure rise time
Result:
ca. 3.85 s

Any other information on results incl. tables

For sample/cellulose runs, only one of the five runs reached a pressure of more than 2070 kPa. Due to the time taken for this run to reach 2070 kPa being significantly slower than the nitric acid/cellulose runs it was decided to terminate the testing.

Pressure rise time (mean, sec) Axenyl BR12 : 41.859

Pressure rise time (mean, sec) Reference : 3.85

Pressure rise time (Axenyl BR12) >> Pressure rise time Reference

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Axenyl BR12 is not a oxidising liquid
Executive summary:

According to EU method A.21 study, Axenyl BR12 is not a oxidising liquid