Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
ASTM D93-16
Deviations:
not specified
GLP compliance:
yes
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
Benzyldodecyldimethylammonium bromide
EC Number:
230-698-4
EC Name:
Benzyldodecyldimethylammonium bromide
Cas Number:
7281-04-1
Molecular formula:
C21H38N.Br
IUPAC Name:
N-benzyl-N,N-dimethyldodecan-1-aminium bromide
Constituent 2
Chemical structure
Reference substance name:
benzyltetradecyldimethylammonium bromide
Cas Number:
18773-88-1
Molecular formula:
C23H42N.Br
IUPAC Name:
benzyltetradecyldimethylammonium bromide
Test material form:
liquid: viscous
Details on test material:
Colour : yellow
Specific details on test material used for the study:
Sample identification : 17.076961.0001
Batch Number:Lot 91602E004 20/06/17
Purity:70% w/w of CAS 7281-04-1 and 30% w/w of CAS 18773-88-1 (stated)
Storage:Store at RT

Results and discussion

Flash point
Key result
Flash point:
> 113 °C
Atm. press.:
>= 100.5 - <= 101.5 kPa
Remarks on result:
no flash point - measurement carried out until boiling temperature

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
No flash was detected before sample start to boil (Flash Point > 114°C)
Executive summary:

In a study according to ASTM D93-16, Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester, no flash was detected before sample start to boil (Flash Point > 114°C)