Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
D-Glucose, reaction products with alcohols C16-18 (even numbered)
IUPAC Name:
D-Glucose, reaction products with alcohols C16-18 (even numbered)
Test material form:
solid: particulate/powder

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
1 050 s
Moisture (wt %):
0.13
Remarks on result:
other: Ignition could be observed. Propagation time exceeded 4 minutes. Performance of the main test was not necessary.

Any other information on results incl. tables

About 25 g of the test item were used to form the test pile (excess substance included). After the flame application to one end of the pile forming of a black molten mass was visible. An ignition of the molten mass substance could be detected. In the preliminary test the propagation time for a distance of 200 mm was 1050 s.

The drying loss of the substance was determined using the drying balance.The result was a value of 0.13 %.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item is not highly flammable according to the criteria in Council Regulation (EC) No 440/2008, test method A.10.
Executive summary:

The flammability of the substance was investigated according to to the method EC A.10. In a preliminary test ignition of the substane was observed. The propagation time for a distance of 200 mm was 1050 seconds. As this time is longer than 4 minutes the performance of the main test was not necessary. The substance is not highly flammable according to the criteria in Council Regulation (EC) No 440/2008, test method A.10.