Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2015

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: In the preliminary screening test the substance doesen't ignite by a hot flame from a gas burner within 2 Minutes. It only melts. Therefore the main test may be omitted.
Remarks:
The test item A130 was formed into a particle train. A hot flame from a gas burner with a diameter of about 6 mm is used to ignite the pile at one end. In the preliminary screening test the substance doesen't ignite by a hot flame from a gas burner within 2 Minutes. It only melts. Therefore the main test may be omitted.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item can be classified as being non flammable.