Registration Dossier

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report Date:
2016

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes (incl. certificate)
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid

Results and discussion

Density
Key result
Type:
relative density
Density:
1.401 other:
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
The relative density of the test item was determined to 1.4005 at 20°C.