Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 24, 2017 to June 09, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
(Z)-hex-3-enyl isobutyrate
EC Number:
255-424-0
EC Name:
(Z)-hex-3-enyl isobutyrate
Cas Number:
41519-23-7
Molecular formula:
C10H18O2
IUPAC Name:
(Z)-hex-3-enyl isobutyrate
Specific details on test material used for the study:
TEST MATERIAL
Name ( stated on the report) : Hexenyl-3-cis Isobutyrate
Appearance: Colourless to pale yellow liquid
Batch: VE00468943
Expiry date: November 12, 2017

Results and discussion

Flash point
Key result
Flash point:
77.5 °C
Atm. press.:
1 013 hPa

Any other information on results incl. tables

The results of the main tests are:

First determination:              Flash point, corrected for atmospheric pressure: 77.5°C

Second determination:       Flash point, corrected for atmospheric pressure: 77.5°C

Applicant's summary and conclusion

Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
The results of the two tests were averaged and rounded off to the nearest 0.5°C to obtain the final flash point value:
Flash point Hexenyl-3-cis Isobutyrate: 77.5°C.
Executive summary:

The flash point of Hexenyl-3-cis Isobutyrate was determined by the Pensky-Martens method according to ISO 2719.

 The result is: 77.5°C