Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 14, 2017 to July 10, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7220 (Boiling Point / Boiling Range)
GLP compliance:
yes (incl. QA statement)
Type of method:
other: method of the capillary tube was used

Test material

Constituent 1
Chemical structure
Reference substance name:
(Z)-hex-3-enyl isobutyrate
EC Number:
255-424-0
EC Name:
(Z)-hex-3-enyl isobutyrate
Cas Number:
41519-23-7
Molecular formula:
C10H18O2
IUPAC Name:
(Z)-hex-3-enyl isobutyrate
Specific details on test material used for the study:
TEST MATERIAL
Name ( stated on the report) : Hexenyl-3-cis Isobutyrate
Appearance: Colourless to pale yellow liquid
Batch: VE00468943
Expiry date: November 12, 2017

Results and discussion

Boiling point
Key result
Boiling pt.:
199 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Conclusions:
From the tests described above, it can be concluded that the standard boiling point of Hexenyl-3-cis Isobutyrate is (values rounded off): 472 K (199°C)
Executive summary:

The boiling point of Hexenyl-3-cis Isobutyrate was measured according to OECD Guideline No. 103 (principle according to Siwoloboff). The result can be expressed as follows (values rounded off):

 The boiling point of Hexenyl-3-cis Isobutyrate:472 K (199°C)