Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27-05-2014 to 13-06-2014
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
other: APAG-FA-004
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Remarks:
Brookfield viscosimeter
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
150
Remarks on result:
other: +/- 2 cP
Temp.:
other: 24 °C
Parameter:
dynamic viscosity (in mPa s)
Value:
146
Remarks on result:
other: +/- 2 cP

 

 

Test 1 (cP)

Test 2 (cP)

 

Viscosity at 20ºC

150.0

144.5

 

Viscosity at 24ºC

149.0

146.5

Viscosity at 20ºC:             150 cP

Viscosity at 24ºC:             146 cP

 

 

Accurancy

+/- 2 cP

Conclusions:
The Viscosity of the test substance was determined according to APAG-FA-004 (determination of Brookfield viscosity). The dynamic viscosity was measured to be 150 cP (20°C) and 146 cP (24°C).
Executive summary:

The Viscosity of the test substance was determined according to APAG-FA-004 (determination of Brookfield viscosity). The dynamic viscosity was measured to be 150 cP (20°C) and 146 cP (24°C).

Description of key information

The Viscosity of the test substance was determined according to APAG-FA-004 (determination of Brookfield viscosity). The dynamic viscosity was measured to be 150 cP (20°C) and 146 cP (24°C).

Key value for chemical safety assessment

Additional information