Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Data waiving:
other justification
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid non flammable in air, e.g. no flash point up to 200°C
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27-05-2014 to 13-06-2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
ASTM D6450-99. This method is correlated with the method ASTM D93
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
> 200 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: vapour pressure estimated; value not mentioned
Interpretation of results:
GHS criteria not met
Conclusions:
ASTM D6450-99. This method is correlated with the method ASTM D93
Executive summary:

The flash point of the test material was determined according to ASTM D6450-99 (method correlated with ASTM D93). The flash point of the test material was measured to be > 200 °C)

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion