Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Data waiving:
other justification
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27-05-2014 to 13-06-2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Qualifier:
according to guideline
Guideline:
other: ASTM E 537-86
GLP compliance:
no
Type of method:
differential scanning calorimetry
Melting / freezing pt.:
< -20 °C
Remarks on result:
other: +/- 0.5 °C

Equipment:

DSC + RCS (TA Instruments)

Model:

 

2010 (S/N 2010CD-5077)

 

 

 

Starting T:

 

 -50ºC

Final T:

 

+50ºC

Rate:

 

5.00ºC/min

Conclusions:
The melting point of the test substance was determined according to OECD102, with DSC to be <-20 °C (+/-0.5°C).
Executive summary:

The melting point of the test substance was determined according to OECD102, with DSC to be <-20 °C (+/-0.5°C).