Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April-June 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study
Cross-reference
Reason / purpose:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Principles of method if other than guideline:
determination carried out using BS 2000 Part 15 (equivalent to ISO 3016), designed to be compatible with Method 102 of the OECD Guidlines for testing chemicals (27 july 1995).
GLP compliance:
yes
Type of method:
pour point

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Sample collection made according to ECI/REACH Copper Consortium Standards Protocols (see IUCLID section 1.4).
sample code AC_B13_625875

Results and discussion

Any other information on results incl. tables

The measured stationary points are shown in the following table:

 Measurementstationary point (K)  Determination 1255 Determination 2255 
 Pour point (K)  258  258

 Mean pour point: 258 +- 3K

Applicant's summary and conclusion

Conclusions:
the pour point of the substance(representative sample) is ca 258K
Executive summary:

The freezing of the substance was determined by measuring the pour point of a representative sample. The mean pour point determined was 258K