Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
N4-[3-(1H-imidazol-1-yl)propyl]-2-methylbenzene-1,4-diamine trihydrochloride
EC Number:
700-345-3
Cas Number:
515851-08-8
Molecular formula:
C13H21Cl3N4
IUPAC Name:
N4-[3-(1H-imidazol-1-yl)propyl]-2-methylbenzene-1,4-diamine trihydrochloride
Constituent 2
Reference substance name:
[TN]Kn 172[/TN][SPEC][/SPEC][AM]96.2%[/AM]
IUPAC Name:
[TN]Kn 172[/TN][SPEC][/SPEC][AM]96.2%[/AM]
Details on test material:
Batch No. Kn-Gi 9328-182

Results and discussion

Test results (Oxidising liquids)
Sample tested:
other: not specified (migrated information) The test item Kn 172 has no oxidizing properties
Parameter:
other: The test item Kn 172 has no oxidizing properties
Result:
other: not applicable
Remarks on result:
other: The test item Kn 172 has no oxidizing properties
Test results (Oxidising solids)
Sample tested:
other: not specified (migrated information) The test item Kn 172 has no oxidizing properties
Parameter:
other: The test item Kn 172 has no oxidizing properties
Result:
other: not applicable
Remarks on result:
other: The test item Kn 172 has no oxidizing properties

Any other information on results incl. tables

The test item Kn 172 has no oxidizing properties

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
The test item Kn 172 has no oxidizing properties