Endpoint:
bulk density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17/06/2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: No guidelines followed
Qualifier:
according to guideline
Guideline:
other: ASTM D 1895 B
Deviations:
not specified
Principles of method if other than guideline:
Bulk density was determined as the weight of material placed into 100ml calibrated cylinder divided to the cylinder volume.
GLP compliance:
no
Type of method:
other: using a calibrated cylinder
Type:
bulk density
Density:
0.97 g/cm³
Temp.:
20 °C

The weight of substance in the cylinder was 97.25 (mean of 5 replicates, RSD=2.6%). The bulk density of substance calculated from the experimental data was 0.97 g/cm3 (RSD=2.6%).

Conclusions:
The bulk density of substance calculated from the experimental data was 0.97 g/cm3 (RSD=2.6%).
Executive summary:

/

Endpoint:
bulk density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
19/01/2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: no guideline followed
Reason / purpose for cross-reference:
reference to same study
Qualifier:
no guideline followed
Principles of method if other than guideline:
Bulk density was determined as the weight of material placed into 100 ml calibrated cylinder divided to the cylinder volume.
GLP compliance:
no
Type of method:
other: calibrated cylinder
Type:
bulk density
Density:
0.96 g/cm³
Remarks on result:
other: no temperature was measured

The following results were obtained: The weight of F2200 in the cylinder was 95.82 (mean of 6 replicates, RSD=1.02%).

The bulk density of F2200 calculated from the experimental data was 0.96 g/cm3 (RSD=1.02%).

Conclusions:
The bulk density of F2200 calculated from the experimental data was 0.96 g/cm3 (RSD=1.02%).

Description of key information

Bulk density of Brominated epoxy having epoxy equivalent of 400gr/eq

Key value for chemical safety assessment

Relative density at 20C:
0.97

Additional information

Bulk density of 0.97g/cm³