Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
not specified
Reliability:
other: not applicable
Rationale for reliability incl. deficiencies:
other: Test not experimantal performed
Data waiving:
study technically not feasible
Justification for data waiving:
other:

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Type of method:
other:

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent

Results and discussion

Any other information on results incl. tables

No flash point determination was carried out due to the inherent properties of RO 1525.

Reason:

The method for determining the flash point is used for liquids whose vapors can

be ignited by sources of ignition.

RO I525 is, however, a powder-form solid with a melting temperature > 300 "C

(see study no. 00-9216-5: Melting temperature of RO 1525). This is why no

flash point determination was carried out.

Any evaluation as a hazardous substance should be carried out according to

the criteriafor solids (A.10 -A.12 -A.l4 -A.l6 -A.17).

Applicant's summary and conclusion

Conclusions:
No flash point determination was carried out due to the inherent properties of RO 1525.
Reason:
The method for determining the flash point is used for liquids whose vapors can
be ignited by sources of ignition.
RO I525 is, however, a powder-form solid with a melting temperature > 300 "C
(see study no. 00-9216-5: Melting temperature of RO 1525). This is why no
flash point determination was carried out.
Any evaluation as a hazardous substance should be carried out according to
the criteriafor solids (A.10 -A.12 -A.l4 -A.l6 -A.17).