Oxidizing Properties:
The OJEC Method A17 test was conducted on the substance. A maximum burn rate was not observed for substance/cellulose mixtures. Chemical compatability testing was conducted on the substance using EPA OPPTS 830.6314 (1996) and in all cases the temperature of the substance/chemical mixtures did not rise above 5 deg C. It was concluded that the substance did not have oxidizing properties.

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

Justification for classification or non-classification

Oxidizing Properties:

The OJEC Method A17 test was conducted on the substance. A maximum burn rate was not observed for substance/cellulose mixtures.

Chemical compatibility testing was conducted on the substance using EPA OPPTS 830.6314 (1996) and in all cases the temperature of the substance/chemical mixtures did not rise above 5 deg C. It was concluded that the substance did not have oxidizing properties.

The substance has been classified as a non-oxidising substance using classification criteria under EU Directive 67/548/EEC.