Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: OECD Guidelne study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
not specified
Key result
Parameter:
lower explosion limit
Remarks on result:
other: n.a
Key result
Parameter:
upper explosion limit
Remarks on result:
other: n.a.
Key result
Type of aerosol tested:
aerosol dispenser: not specified
Remarks:
or specified in description of method (migrated information)
Test parameter:
ignition distance (cm)
Remarks:
original parameter: flame extension (cm) (migrated information)
Remarks on result:
other: n.a.
Key result
Type of aerosol tested:
aerosol dispenser: not specified
Remarks:
or specified in description of method (migrated information)
Test parameter:
maximum flame height (cm)
Remarks:
original parameter: flame projection (cm) (migrated information)
Remarks on result:
other: n.a
Key result
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: no burning time reported
Key result
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
other: no ignition reported
Key result
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
other: no ignition reported
Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The sample should not be considered as flammable.

Description of key information

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification