Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20/2/2016 - 20/2/2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental result using standard methods of analysis
Qualifier:
according to guideline
Guideline:
ISO No., other: as below
Principles of method if other than guideline:
The flash point determination of Test item was done. The method is closed cup method using Pensky-Martens Flash Point Apparatus.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Name of test material : 5-methoxy-1,3-dihydro-2H-benzimidazole-2-thione
- Molecular formula : C8H8N2OS
- Molecular weight : 180.2302 g/mol
- Smiles notation : COc1ccc2c(c1)nc([nH]2)S
- InChl : 1S/C8H8N2OS/c1-11-5-2-3-6-7(4-5)10-8(12)9-6/h2-4H,1H3,(H2,9,10,12)
- Substance type : Organic
- Physical state : Solid
Key result
Flash point:
141.6 °C
Atm. press.:
978.5 hPa
Remarks on result:
other: No other detail available

TEST DESCRIPTION AND RESULT

Method Details

Observations

Remarks if, any

Method

Closed cup method using Pensky-Martens Flash Point Apparatus

 

 

Principle of Flash point test

The flash point of a flammable liquid is the lowest temperature at which there will be enough flammable vapor to ignite when an ignition source is applied.

 

 

Type of method

·    Closed cup

 

 

Flash point apparatus

·    Abel’s flash pt apparatus

·    Pensky-Martens flash point apparatus

Pensky-Martens flash point apparatus

 

Quantity of test item used

g

5 g

 

Ignition source

Gas lighter/flame

Gas lIghter

 

Atmospheric pressure

hPa

978.5 hPa

 

 Mean Flash point (RESULT)

°C

141.6°C

 

 

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 141.6°C at 978.5 hPa.
Executive summary:

The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 141.6°C at 978.5 hPa.

Description of key information

The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 141.6°C at 978.5 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
141.6 °C

Additional information

The flash point determination of test chemical was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 141.6°C at 978.5 hPa.