Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14 February - 24 June 2003
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Version / remarks:
Official Journal of the European Communities L383A volume 35, 29 December 1992
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
negative (not further specified)
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
negative (not further specified)
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
negative (not further specified)

Thermal sensitivity (effect of flame) -no explosion was observed.


Mechanical sensitivity (shock): Six time negative, sensitivity >40 Nm.


Mechanical sensitivity (friction): Six times negative, sensitivity >360 N.

Interpretation of results:
other: no classification according to REGULATION (EC) 1272/2008
Conclusions:
Thermal sensitivity (effect of a flame): The test substance does not explode under the effect of a flame.

Mechanical sensitivity (shock): The test substance is not sensitive to impact.

Mechanical sensitivity (friction): The test substance is not sensitive to friction.

Description of key information

not explosive (EU A.14)

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Thermal sensitivity (effect of a flame): The test substance does not explode under the effect of a flame.

Mechanical sensitivity (shock): The test substance is not sensitive to impact.

Mechanical sensitivity (friction): The test substance is not sensitive to friction.

Justification for classification or non-classification