Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 247-477-3 | CAS number: 26140-60-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
General: Wash clothing before reuse.
Eye contact: Wash with plenty of water.
Skin contact: Wash with plenty of water.
Inhalation: Remove patient to fresh air.
Fire-fighting measures
Extinguishing media: Water spray, foam, dry chemical, or carbon dioxide
Exposure hazards: None known
Combustion products: None known
Protective equipment: Firefighters, and others exposed, wear self-contained breathing apparatus. Equipment should be thoroughly decontaminated after use.
Accidental release measures
Personal precautions: Use personal protection recommended in section 8 of the Safety Data Sheet.
Environmental precautions: Keep out of drains and water courses.
Methods for cleaning up: Contain large spills with dikes and transfer the material to appropriate containers for reclamation or
disposal. Absorb remaining material or small spills with an inert material and then place in a chemical waste container. Flush spill area with water.
Handling and storage
Handling: Good industrial practice in housekeeping and personal hygiene should be followed. Avoid breathing vapour or mist.
Engineering measures: Provide natural or mechanical ventilation to control exposure levels below airborne exposure limits. If practical, use local mechanical exhaust ventilation at sources of air contamination such as processing equipment.
Storage: Stable under normal conditions of handling and storage.
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- UN3077
Shipping information
- Proper shipping name and description:
- Environmentally hazardous substance, solid, N.O.S.
- Chemical name:
- Terphenyls
- Language:
- English
- Labels:
- 9
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- UN3077
Shipping information
- Proper shipping name and description:
- Environmentally hazardous substance, solid, N.O.S.
- Chemical name:
- Terphenyls
- Language:
- English
- Labels:
- 9
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- UN3077
Shipping information
- Proper shipping name and description:
- Environmentally hazardous substance, solid, N.O.S.
- Chemical name:
- Terphenyls
- Labels:
- 9
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- UN3077
Shipping information
- Proper shipping name and description:
- Environmentally hazardous substance, solid, N.O.S.
- Chemical name:
- Terphenyls
- Labels:
- 9
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Occupational exposure limit -terphenyl:
ACGIH TLV: 5 mg/m3 ; ; ceiling
Austria : MAK (Maximum concentration in workplace): 0,5 ml/m3 ; 4,5 mg/m3 ; ; ceiling
Belgium: KORTETIJDSWAARDE / VALEUR COURTE DURÉE (15 min): 0,53 ml/m3 ; 5 mg/m3 ; ; ceiling
Denmark : Grænseværdier for Stoffer og Materialer (TWA) :: 0,5 ml/m3 ; 5 mg/m3 ; ; 8-hr TWA
Finland : Työministeriö, Kemian Työsuojeluneuvottelukunta (15-minute) :: 3 ml/m3 ; 29 mg/m3 ; ; 15-min STEL
Finland : Työministeriö, Kemian Työsuojeluneuvottelukunta (8-hour) :: 1 ml/m3 ; 10 mg/m3 ; ; 8-hr TWA
France : VLE (Exposure limit value): 0,5 ml/m3 ; 5 mg/m3 ; ; 15-min STEL
Germany : MAK (Maximum concentration in workplace): 5 mg/m3 ; inhalable dust ;
Greece : Occupational Exposure Limits: 0,5 ml/m3 ; ; 15-min STEL
Netherlands : MAC (Maximum concentration on workplace): 0,5 ml/m3 ; 4,5 mg/m3 ; ; ceiling
Ireland : OEL (Occupational Exposure Limit): 0,5 ml/m3 ; 5 mg/m3 ; ; 15-min STEL
Italy : Occupational Exposure Limits (OEL) :: 0,53 ml/m3 ; 5 mg/m3 ; ; ceiling
Switzerland : Grenzwerte am Arbeitsplatz (TWA) :: 0,5 ml/m3 ; 5 mg/m3 ; ; 8-hr TWA
Norway : Administrative Norms for Contaminants in the Workplace (TLV) :: 0,5 ml/m3 ; 4,5 mg/m3 ; ; ceiling
Spain : Occupational Exposure Limits (VLA-EC) :: 0,52 ml/m3 ; 5 mg/m3 ; ; 15-min STEL
Portugal : Occupational Exposure Limits (OEL): 5 mg/m3 ; ; ceiling
UK : OES (Occupational Exposure Standard): 0,5 ml/m3 ; 4,8 mg/m3 ; ; 15- min STEL
Slovenia - Occupational Exposure Limits: 5 mg/m3 ; inhalable dust ; 8-hr TWA
Respiratory protection: Avoid breathing vapour or mist. Use approved respiratory protection equipment (e.g. combination filter A/P2) when airborne exposure limits are exceeded. Consult the respirator manufacturer to determine the appropriate type of equipment for a given application. Observe respirator use limitations specified by the manufacturer.
Hand protection: Although this product does not present a significant skin concern, minimize skin contamination by following good industrial practice. Wearing protective gloves is recommended.
Eye protection: Does not cause significant eye irritation or eye toxicity requiring special protection. Use good industrial practice to avoid eye contact.
Skin protection: Although this product does not present a significant skin concern, minimize skin contamination by following good industrial practice. Wash contaminated skin thoroughly after handling.
Stability and reactivity
Conditions to avoid: All sources of ignition.
Materials to avoid: Contact with strong oxidizing agents.
Hazardous reactions: Hazardous polymerization does not occur.
Hazardous decomposition products: None known
Disposal considerations
European waste catalog No. 13 03 08 - synthetic insulating and heat transferring oils
Burn only in proper incinerator.
All local and national regulations should be followed.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.