Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Endpoint:
melting point/freezing point
Type of information:
migrated information: read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Study period:
05 Feb 2005 (first data acquisition), 01 Apr 2005 (final data acquisition).
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP-guideline study, tested with the source substance CAS 1318-02-1. According to the ECHA Guidance Document "Practical guide 6: How to report read-across and categories (March 2010)", the reliability was changed from RL1 to RL2.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2005
Report date:
2005

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
yes
Remarks:
Batch identities, expiry dates and purities for the test substances were not supplied by the Sponsor
GLP compliance:
yes
Type of method:
other: differential scanning calorimetry (DSC)

Test material

Constituent 1
Reference substance name:
Automatically generated during migration to IUCLID 6, no data available
IUPAC Name:
Automatically generated during migration to IUCLID 6, no data available
Details on test material:
- Name of test material (as cited in study report): 3A Powder Adsorbent
- Chemical name: Zeolite, cuboidal, crystalline, synthetic, non-fibrous
- Framework: cuboidal
- Related CAS number: 1318-02-1
- Physical state: White powder
- Analytical purity: no data
- Storage condition of test material: Room temperature, 10 to 30°C

Results and discussion

Melting / freezing point
Melting / freezing pt.:
> 400 °C

Any other information on results incl. tables

The thermograms displayed only a falling baseline, with no significant endotherms or exotherms. It is concluded that this material does not undergo melting, boiling or decomposition in the temperature range 20 to 400°C.

Applicant's summary and conclusion