Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April, 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: study acc. to GLP
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Remarks:
registration No.: 17/2015/DPL, Bureau for Chemical Substances
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
0 s
Remarks on result:
other: Sample did not ignite after 120 s of applying the flame of burner.
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Preliminary screening test

The preliminary screening test was made to determine if, on ignition by a gas flame, propagation by burning with flame or smoulldering occurs. It was noted whether combustion propagates along 200 mm of the train within the 4 minutes period. The substance was formed into an unbroken strip or powder train about 250 mm long by 20 mm wide by 10 mm high on a non-combustible, non-porous and low-conducting base plate. A hot flame from gas burner (minimum diameter 5 mm, temperature of the flame was about 100 oC) was applied to one end of the train until the train ignites or for maximum of 2 minutes.

Results of preliminary test

Test number

Time of burning [s]

Comments

Test-1

-

Sample did not ignite. Time of applying the flame of burner: 30, 60, 120 s.

Result: NEGATIVE

Test-2

-

Test-3

-

 Since the result is negative, it is not necessary to go to the next stage of determination.

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Fe(III)IDHA is not highly flammable in accordance with Test A.10 criteria.
Executive summary:

The preliminary screening test was made to determine if, on ignition by a gas flame, propagation by burning with flame or smoulldering occurs.

The substance was formed into an unbroken strip or powder train about 250 mm long by 20 mm wide by 10 mm high on a non-combustible, non-porous and low-conducting base plate. A hot flame from gas burner (minimum diameter 5 mm, temperature of the flame was about 100 oC) was applied to one end of the train until the train ignites or for maximum of 2 minutes.

During 3 trials the sample did not ignite. Time of applying the flame of burner was: 30, 60, 120 s. Since the result was negative, it was not necesary to go to the next stage of determination.

Fe(III)IDHA is not highly flammable in accordance with Test A.10 criteria.

Description of key information

Fe(III)IDHA is not highly flammable in accordance with Test A.10 criteria.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Since the result of preliminary test was negative, it was not necessary to go to the next stage of determination.

Justification for classification or non-classification