Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
hydrolysis
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 November 2017 to 20 March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 111 (Hydrolysis as a Function of pH)
Version / remarks:
13 April 2004
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.7 (Degradation: Abiotic Degradation: Hydrolysis as a Function of pH)
Version / remarks:
EC No. 440/2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
- Batch No.of test material: PFW160141
- Purity: 99.5%
- Expiration date of the lot/batch: 30 December 2018
- Stability under test conditions: Room temperature in the dark
Radiolabelling:
no
Buffers:
The test system consisted of buffer solutions at pH’s 4, 7 and 9.
Buffer Solution Specification:
Buffer solution (pH) Components Concentration (mmol dm-3)
4 Citric acid 6
Sodium chloride 4
Sodium hydroxide 7
7 Disodium hydrogen orthophosphate (anhydrous) 3
Potassium dihydrogen orthophosphate 2
Sodium chloride 2
9 Disodium tetraborate 1
Sodium chloride 2

The buffer solutions were passed through a 0.2 µm membrane filter to sterilize and subjected to ultrasonication and degassing with nitrogen to minimize dissolved oxygen.
Details on test conditions:
Preparation of the Test Solutions
Stock solutions of test item were prepared at a nominal concentration of 1.0 g/L in the three buffer solutions. The stock solutions were adjusted to the nominal pH of the relevant buffer solution and then split into individual glass vessels, sealed with minimal headspace, for each data point. These sample solutions were shielded from light whilst maintained at the test temperature.

Preliminary Test/Tier 1
Sample solutions at pH 4, 7 and 9 were maintained at 50.0 ± 0.5 °C for a period of 120 hours.

Tier 2
Results from the Preliminary test/Tier 1 showed it was not necessary to undertake further testing at pH 4, 7 and 9.
Test performance:
The linearity of the detector response with respect to concentration was assessed over the nominal concentration range of 2 to15 mg/L. The results were satisfactory with correlation coefficient (r) of ≥ 0.992 being obtained.
Transformation products:
no
Key result
pH:
4
Temp.:
25 °C
DT50:
> 1 yr
Remarks on result:
hydrolytically stable based on preliminary test
Key result
pH:
7
Temp.:
25 °C
DT50:
> 1 yr
Remarks on result:
hydrolytically stable based on preliminary test
Key result
pH:
9
Temp.:
25 °C
DT50:
> 1 yr
Remarks on result:
hydrolytically stable based on preliminary test
Details on results:
No significant peaks were observed at the approximate retention time of the test item on analysis of any matrix blank solutions.

The mean peak areas relating to the standard and sample solutions are shown in Table 1

Table 1:

Solution

Mean Peak Area

Standard 10.0 mg/L, pH 4

1.397 x 107

Standard 10.1 mg/L, pH 4

1.457 x 107

Initial Sample A, pH 4

1.174 x 107

Initial Sample B, pH 4

1.044 x 107

24 Hour Sample A, pH 4

1.139 x 107

24 Hour Sample B, pH 4

1.080 x 107

Standard 10.0 mg/L, pH 7

1.370 x 107

Standard 10.1 mg/L, pH 7

1.371 x 107

Initial Sample A, pH 7

1.068 x 107

Initial Sample B, pH 7

1.042 x 107

24 Hour Sample A, pH 7

1.058 x 107

24 Hour Sample B, pH 7

1.036 x 107

Standard 10.0 mg/L, pH 9

1.366 x 107

Standard 10.1 mg/L, pH 9

1.374 x 107

Initial Sample A, pH 9

1.295 x 107

Initial Sample B, pH 9

1.276 x 107

24 Hour Sample A, pH 9

1.303 x 107

24 Hour Sample B, pH 9

1.276 x 107

Standard 10.0 mg/L, pH 4

1.397 x 107

Standard 10.1 mg/L, pH 4

1.400 x 107

120 Hour Sample A, pH 4

1.108 x 107

120 Hour Sample B, pH 4

1.116 x 107

Standard 10.0 mg/L, pH 7

1.389 x 107

Standard 10.1 mg/L, pH 7

1.402 x 107

120 Hour Sample A, pH 7

1.110 x 107

120 Hour Sample B, pH 7

1.080 x 107

Standard 10.0 mg/L, pH 9

1.377 x 107

Standard 10.1 mg/L, pH 9

1.404 x 107

120 Hour Sample A, pH 9

1.361 x 107

120 Hour Sample B, pH 9

1.335 x 107

The test item concentrations at the given time points are shown in the following tables:

Table 2          pH 4 at 50 ºC

Time (Hours)

Concentration (g/L)

% of Mean Initial Concentration

A

B

A

B

0

0.826

0.734

-

-

24

0.801

0.760

103

97.4

120

0.796

0.802

102

103

pH 4 at 50 °C result:  Less than 10% hydrolysis after 5 days at 50 °C, equivalent to a half-life greater than 1 year at 25 °C.

Table 3          pH 7 at 50 ºC

Time (Hours)

Concentration (g/L)

% of Mean Initial Concentration

A

B

A

B

0

0.782

0.763

-

-

24

0.775

0.759

100

98.2

120

0.798

0.777

103

101

pH 7 at 50 °C result:  Less than 10% hydrolysis after 5 days at 50 °C, equivalent to a half-life greater than 1 year at 25 °C.

Table 4          pH 9 at 50 ºC

Time (Hours)

Concentration (g/L)

% of Mean Initial Concentration

A

B

A

B

0

0.950

0.935

-

-

24

0.956

0.935

101

99.3

120

0.983

0.964

104

102

pH 9 at 50 °C result:  Less than 10% hydrolysis after 5 days at 50 °C, equivalent to a half-life greater than 1 year at 25 °C.

 Discussion

No significant peaks were observed at the approximate retention time of the test item on analysis of any matrix blank solutions.

Validity criteria fulfilled:
yes
Conclusions:
Hydrolysis as function of pH of JeffCat TAP has been determined according to OECD guideline 111 under GLP procedure. At pH 4, 7 and 9, a decrease in concentration < 10 % was observed after 5 days (half-life time > 1 year). Hence it was concluded that the test substancel is hydrolytically stable at pH 4, 7 and 9.

Description of key information

One study (Covance, 2019) was performed according to OECD guideline 111 and regarded as a key study (Klimisch score of 1). A half-life time of > 1 year at 25 °C was determined for the test substance.

Key value for chemical safety assessment

Additional information

Hydrolysis was studied in a guideline study (OECD Guideline 111) during 5 days at pH 4, 7 and 9 and at 50°C. Less than 10% hydrolysis was observed at the end of testing at each pH level tested. Based on these results, no further testing was needed and it was concluded that the estimated half-life at 25°C is > 1 yr (substance hydrolytically stable). The results of the test can be considered reliable without restriction.