Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

General advice :

Move out of dangerous area.

Consult a physician.

Show this safety data sheet to the doctor in attendance.

Symptoms of poisoning may appear several hours later.

Do not leave the victim unattended.

If inhaled :

If unconscious place in recovery position and seek medical advice.

If symptoms persist, call a physician.

In case of skin contact :

Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty.

Take victim immediately to hospital.

If on skin, rinse well with water.

If on clothes, remove clothes.

In case of eye contact :

Small amounts splashed into eyes can cause irreversible tissue damage and blindness.

In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.

Continue rinsing eyes during transport to hospital.

Remove contact lenses.

Protect unharmed eye.

Keep eye wide open while rinsing.

If eye irritation persists, consult a specialist.

If swallowed :

Clean mouth with water and drink afterwards plenty of water.

Keep respiratory tract clear.

Do NOT induce vomiting.

Do not give milk or alcoholic beverages.

Never give anything by mouth to an unconscious person.

If symptoms persist, call a physician.

Take victim immediately to hospital.

Fire-fighting measures

Suitable extinguishing media :

Carbon dioxide (CO2)

Dry chemical

Foam

Unsuitable extinguishing media :

High volume water jet

Specific hazards during firefighting :

Do not allow run-off from fire fighting to enter drains or water courses.

Hazardous combustion products :

No hazardous combustion products are known

Specific extinguishing methods :

No data is available on the product itself.

Further information :

Collect contaminated fire extinguishing water separately. This must not be discharged into drains.

Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

For safety reasons in case of fire, cans should be stored separately in closed containments.

Use a water spray to cool fully closed containers.

Special protective equipment for firefighters :

Wear self-contained breathing apparatus for firefighting if necessary.

Accidental release measures

Personal precautions, protective equipment and emergency procedures :

No action shall be taken involving any personal risk or without suitable training.

Remove all sources of ignition.

Use personal protective equipment.

Evacuate personnel to safe areas.

Ensure adequate ventilation.

In case of inadequate ventilation wear respiratory protection.

Environmental precautions :

Prevent product from entering drains.

Prevent further leakage or spillage if safe to do so.

If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and materials for containment and cleaning up :

Neutralise with acid.

Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations.

Keep in suitable, closed containers for disposal.

Handling and storage

Advice on protection against fire and explosion :

Do not spray on a naked flame or any incandescent material. Keep away from open flames, hot surfaces and sources of ignition.

Advice on safe handling :

Avoid formation of aerosol.

Do not breathe vapours/dust.

Avoid exposure - obtain special instructions before use.

Avoid contact with skin and eyes.

Smoking, eating and drinking should be prohibited in the application area.

Provide sufficient air exchange and/or exhaust in work rooms.

To avoid spills during handling keep bottle on a metal tray.

Dispose of rinse water in accordance with local and national regulations.

Persons susceptible to skin sensitisation problems or asthma, allergies, chronic or recurrent respiratory disease should not be employed in any process in which this mixture is being used.

Conditions for safe storage :

Prevent unauthorized access.

No smoking.

Keep container tightly closed in a dry and well-ventilated place.

Containers which are opened must be carefully resealed and kept upright to prevent leakage.

Electrical installations / working materials must comply with the technological safety standards.

Materials to avoid :

Heat

Nitrites

Keep away from oxidizing agents.

Keep away from strong acids.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN 2922
Shippingopen allclose all
Labels:
8 + 6.1
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN 2922
Shipping information
Proper shipping name and description:
Corrosive liquid, toxic, n.o.s.
Chemical name:
1-(DIMETHYLAMINOETHYL)-4-METHYLPIPERAZINE
Labels:
8 + 6.1
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN 2922
Shipping information
Proper shipping name and description:
Corrosive liquid, toxic, n.o.s.
Chemical name:
1-(DIMETHYLAMINOETHYL)-4-METHYLPIPERAZINE
Labels:
8 + 6.1
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Respiratory protection :

Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary.

Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

Hand protection

Remarks :

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary.

Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties.

It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers.

In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated.

Eye protection :

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists or dusts.

If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection:

Tightly fitting safety goggles

Eye wash bottle with pure water

Wear face-shield and protective suit for abnormal processing problems.

Ensure that eyewash stations and safety showers are close to the workstation location.

Skin and body protection :

Impervious clothing

Choose body protection according to the amount and concentration of the dangerous substance at the work place.

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Hygiene measures :

Avoid contact with skin, eyes and clothing.

When using do not eat or drink.

When using do not smoke.

Wash hands before breaks and immediately after handling the product.

Stability and reactivity

Reactivity :

No dangerous reaction known under conditions of normal use.

Chemical stability :

Stable under normal conditions.

Possibility of hazardous reactions :

Vapours may form explosive mixture with air.

No decomposition if stored and applied as directed.

Conditions to avoid :

Heat, flames and sparks.

Incompatible materials :

Acids

Oxidizing agents

Hazardous decomposition products :

Carbon monoxide Carbon dioxide (CO2) Nitrogen oxides (NOx) Aldehydes Ammonia Ketones

Disposal considerations

Waste from residues :

The product should not be allowed to enter drains, water courses or the soil.

Do not contaminate ponds, waterways or ditches with chemical or used container.

Send to a licensed waste management company.

Contaminated packaging :

Empty remaining contents.

Dispose of as unused product.

Do not re-use empty containers.

Do not burn, or use a cutting torch on, the empty drum.