Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
5 February 1993 to 22 February 1993
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
yes
Remarks:
The concentration of the test substance in the stock solution is 0.1 g/L in water, instead 0.5 g/L.
GLP compliance:
yes
Analytical monitoring:
no
Details on sampling:
Not performed
Vehicle:
no
Details on test solutions:
Not specified
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
Organism: Activated sludge of a communal sewage treatment plant (ARA-Pro Rheno Basel)Sludge pretreatment: 3 times washing with tap water and addition of synthetic sewage (a day before the main test)
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Post exposure observation period:
No post exposure observation period specified
Hardness:
No data
Test temperature:
20.4°C
pH:
6.4 before the test beginning
Dissolved oxygen:
No data
Salinity:
No data
Conductivity:
No data
Nominal and measured concentrations:
Nominal: 64, 20 and 6.4 mg/L of the test substance
Nominal: 32,10 and 3.2 mg/L of the reference substance
Details on test conditions:
Temperature: 20.4°C
Sludge dry weight: 1.56 g/L
Test volume: 100 mL
Test duration: 3h
Estimation technique: O2 - consumption, measured with an oxygen sensitive electrode system: OXI DIGI 530 (SAV : 00 109)
Aeration: 0.1 - 0.2 L/min by pasteur-pipette
pH of sludge: 6.4 before the test beginning
Reference substance (positive control):
yes
Remarks:
3,5-Dichlorophenol
Key result
Duration:
3 h
Dose descriptor:
IC50
Effect conc.:
> 64 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Details on results:
Substance is miscible in water -> dispersion
Results with reference substance (positive control):
The IC50 of the reference substance 3,5-Dichlorophenol : 8.0 mg/l.
Reported statistics and error estimates:
No data

 

Control

pH after 3 h

1)

O2-consumption (in cm)

2)

time

(in cm)

mg O2/min/l

 

C1

C1

7.6

7.5

4.2

4.2

3.8

4.1

0.88

0.82

Φ C 0.85

 

Test substance (mg/l)

pH after 3 h

1)

O2-consumption

(in cm)

2)

time

(in cm)

mg O2

pro min/l

%

of control

%

inhibition

64

7.3

4.9

4.4

0.89

104.71

0.00

20

7.5

4.5

4.2

0.86

101.18

0.00

6.4

7.6

4.3

4.1

0.84

98.62

1.18

 

3,5-Dichlorophenol (mg/l)

pH after 3 h

1)

O2-consumption

(in cm)

2)

time

(in cm)

mg O2

pro min/l

%

of control

%

inhibition

32

7.7

0.8

5.3

0.12

14.12

85.88

10

7.7

2.3

4.8

0.38

44.71

55.29

3.2

7.7

3.9

5.2

0.60

70.59

29.41

 

C = Control

1)2 cm = 0.8 mg/l O2

2)2 cm = 1 min

 

Remark: Substance is miscible in water → dispersion

Validity criteria fulfilled:
yes
Conclusions:
The IC50 (3 h) of the test material : > 64.0 mg/l.
Executive summary:

The toxicity of the test material to activated sludge was determined in a 3-hours respiration inhibition test according to the OECD Guideline No. 209, and performed in compliance with the Good Laboratory Practice (GLP) Regulations of Switzerland.

 

The test substance concentrations tested were 64, 20 and 6.4 mg/l. The reference substance 3,5-Dichlorophenol was tested in concentrations of 32,10 and 3.2 mg/l.

 

Results:

IC50 of the test material: > 64.0 mg/l

IC50 of the reference substance: 8.0 mg/l

Description of key information

Key value determined in a GLP accredited laboratory study performed in accordance with OECD Guideline No. 209.

Key value for chemical safety assessment

EC50 for microorganisms:
64 mg/L

Additional information

The toxicity of the substance to activated sludge was evaluated in a GLP study conducted in accordance with OECD Guideline No. 209. The substance concentrations tested were 64, 20 and 6.4 mg/L. The IC50 of the test material was determined to be > 64.0 mg/L.