Description of key information

Key value determined in a GLP accredited laboratory test in accordance with OECD Guideline 209. 

Key value for chemical safety assessment

EC50 for microorganisms:
1 000 mg/L

Additional information

A study was performed to assess the effect of the test item on the respiration of activated sewage sludge.

Activated sewage sludge was exposed to an aqueous dispersion of the test item at concentrations of 10, 100 and 1000 mg/L (3 replicates of the 1000 mg/L test concentration) for a period of 3 hours at a temperature of 20 ± 2 °C with the addition of a synthetic sewage as a respiratory substrate. The rate of respiration was determined after 3 hours contact time and compared to data for the control and a reference item, 3,5-dichlorophenol.

 

Inspection of the oxygen consumption data showed that there was no significant effect on the respiration rate. Therefore the 3-Hour EC50 value was determined to be greater than 1000 mg/L. The reference item gave a 3-Hour EC50 value of 12 mg/L.